uPVC systems

Showing 1–12 of 43 results


  • uPVC window systems

    • Watertightness 9A
    • Resistance to high wind loads up to class C5 / B5
    • Air permeability, class 4
    • Sound reduction values up to 44 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W / m2K) 1.2
    • Heat transfer coefficient of the window up to UW (W / m2K)*, 1.0
    • *Sizes: 1,230 x 1,480 mm and Ug= 0.6 W / m2K
    • Installation depth in mm 82
  • Inoform Inoform 82 MD

    uPVC window systems

    • Watertightness 1050 E
    • Resistance to high wind loads up to class C5 / B5
    • Air permeability, class 4
    • Sound reduction values up to 47 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W / m2K) 1.0
    • Heat transfer coefficient of the window up to UW (W / m2K)*, 0.9
    • *Sizes: 1,230 x 1,480 mm and Ug= 0.6 W / m2K 
    • Installation depth in mm 82
  • Inoform Inoform 70 MD

    uPVC system for windows

    • Watertightness E 1050
    • Resistance to high wind loads up to class C5 /B5
    • Air permeability, class 4
    • Sound reduction values up to 46 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,2
    • Heat transfer coefficient of the window UW (W/m2K)*, 1,3
    • *Sizes:: 1.230 x 1.480 mm und Ug=1,0 W/m2K 
    • Installation depth mm 70
  • Inoform Inoform 70 AD

    uPVC system for windows

    • Watertightness                                 9A
    • Resistance to high wind loads up to class C5 /B5
    • Air permeability, class 4
    • Sound reduction values up to 43 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K)           1,3
    • Heat transfer coefficient of the window UW (W/m2K)* 1,3
    • *Sizes: 1.230 x 1.480 mm and                                    Ug=1,0 W/m2K 
    • Installation depth mm  70
  • HYBRID DESIGN PVCu / ALUMINIUM

    • Watertightness 9A
    • Resistance to high wind loads up to class C5 / B5
    • Air permeability, class 4
    • Sound reduction values up to 47 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,0
    • Thermal insulation Uw(W/m2K)*, 0,9
    • *Sizes: 1.230 x 1.480 mm and Ug=0,6 W/m2K
    • Installation depth mm 88
  • LIFT AND SLIDE DOOR uPVC SYSTEM

    • Watertightness 9A
    • Resistance to high wind loads up to class C1 / B2
    • Air permeability, class 4
    • Sound reduction values up to  45 dB
    • Burglary protection up to resistance class RC3
    • Thermal insulation Uf (W/m2K) έως 1,2
    • Thermal insulation UD (W/m2K)* 1,0
    • *Sizes: 3.000 x 2.300 mm and Ug=0,7 W/m2K 
    • Leaf Depth in mm 88
  • LIFT AND SLIDE HYBRID DESIGN PVCu / ALUMINIUM DOOR

    • Watertightness 6A – 9A
    • Resistance to high wind loads up to class C1 / B2
    • Air permeability, class 4
    • Sound reduction values up to  42 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,4
    • Thermal insulation UD (W/m2K)* 1,0
    • *Sizes: 3.000 x 2.300 mm and Ug=0,7 W/m2K 
    • Leaf Depth in mm 76
  • LIFT AND SLIDE DOOR PVCu SYSTEM

    • Watertightness 6A – 9A
    • Resistance to high wind loads up to class C1 / B2
    • Air permeability, class 4
    • Sound reduction values up to 42 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,4
    • Thermal insulation UD (W/m2K)* 1,0
    • *Sizes: 3.000 x 2.300 mm and Ug=0,7 W/m2K
    • Leaf Depth in mm 76
  • PVCu PATIO DOOR SYSTEM

    • Watertightness 5A
    • Resistance to high wind loads up to class C1 / B2
    • Air permeability, class 4
    • Sound reduction values up to 34 dB
    • Burglary protection up to resistance class NPD
    • Thermal insulation Uf (W/m2K) 2,4
    • Thermal insulation Uw(W/m2K)* 1,8
    • *Sizes: 1.230 x 1.480 mm and Ug=1,1 W/m2K
    • Installation depth mm 80
  • HYBRID DESIGN PVCu / ALUMINIUM

    • Watertightness 9A
    • Resistance to high wind loads up to class C5 / B5
    • Air permeability, class 4
    • Sound reduction values up to 47 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,0
    • Thermal insulation Uw(W/m2K)*, 0,9
    • *Sizes: 1.230 x 1.480 mm and Ug=0,6 W/m2K
    • Installation depth mm 88
  • uPVC WINDOW SYSTEMS FOR THE PASSIVE HOUSE

    • Watertightness 9A
    • Resistance to high wind loads up to class C5 / B5
    • Air permeability, class 4
    • Sound reduction values up to 47 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,0
    • Thermal insulation Uw(W/m2K)*, 0,9
    • *Sizes: 1.230 x 1.480 mm and Ug=0,6 W/m2K
    • Installation depth mm 88
  • HYBRID DESIGN PVCu / ALUMINIUM

    • Watertightness 9A
    • Resistance to high wind loads up to class C5 / B5
    • Air permeability, class 4
    • Sound reduction values up to 46 dB
    • Burglary protection up to resistance class RC2
    • Thermal insulation Uf (W/m2K) 1,1
    • Thermal insulation Uw(W/m2K)*, 1,0
    • Sizes: 1.230 x 1.480 mm and Ug=0,6 W/m2K 
    • Installation depth mm 76

Showing 1–12 of 43 results